Productdetails:
|
| voeding: | AC200-240V 50 / 60Hz | magnetiserende stroom: | 8A (8A * 400T = 3200AT) |
|---|---|---|---|
| Centraal magnetisch veld: | Maximaal 110 g | Demagnetiseringsstroom: | 8-0A |
| Tijdelijk ladingstarief: | > 30% | ||
| Markeren: | closed type coil flaw detector,over temperature alarm flaw detector,demagnetization non destructive testing equipment |
||
Over Temperature Alarm Magnetization Closed Type Coil Flaw Detector with Demagnetization
I. Main parameter
1, Input current: 8A, determined according to the set values of magnetization and demagnetization, the standby current is 0.5A;
2, Power supply: AC200-240V 50 / 60Hz;
3, Magnetizing current: 8A (8A * 400T = 3200AT);
4, Central magnetic field: Max 110Gs;
5, Demagnetization current: 8-0A;
6, Coil size: Φ 300mm, 400 turns in total;
7, Temporary load rate: > 30%;
II. Model guide
|
Model name |
Coil diameter |
AC mode, working current |
FWDC mode, working current |
AC&FWDC mode, working current |
|
HCDX-C200 |
8inch |
15A |
||
|
HCDX-C250 |
10inch |
15A |
||
|
HCDX-C280 |
11inch |
15A |
||
|
HCDX-C300 |
12inch |
15A |
||
|
HCDX-C350 |
14inch |
20A |
||
|
HCDX-C400 |
16inch |
25A |
||
|
HCDX-C200DC |
8inch |
|
10A |
|
|
HCDX-C250DC |
10inch |
|
10A |
|
|
HCDX-C280DC |
11inch |
|
10A |
|
|
HCDX-C300DC |
12inch |
|
10A |
|
|
HCDX-C350DC |
14inch |
|
15A |
|
|
HCDX-C400DC |
16inch |
|
15A |
|
|
HCDX-C200AD |
8inch |
|
15/8A |
|
|
HCDX-C250AC |
10inch |
|
15/8A |
|
|
HCDX-C280AD |
11inch |
|
15/8A |
|
|
HCDX-C300AD |
12inch |
|
15/7A |
|
|
HCDX-C350AD |
14inch |
|
20/10A |
|
|
HCDX-C400AD |
16inch |
|
25/12A |
Optional function: Demagnetization, foot switch
III. Function introduction
1, Magnetization - start the electromagnetic field to magnetize the workpiece;
2, Demagnetization - demagnetization field starts to demagnetize the workpiece;
3, Over temperature alarm - the coil has a built-in 75 ℃ temperature sensor. When the set temperature is exceeded, it enters the protection state;
IV. Installation and commissioning
Installation:
1. The equipment shall be installed in a dry environment without metal dust, corrosive gas and inflammable and explosive articles;
2. The temperature of surrounding medium shall not be lower than - 10 ℃ and not higher than + 40 ℃;
3. The relative humidity of the air shall not be greater than 85%;
4. The pipe and wire connection between the installation equipment and each auxiliary facility shall be connected according to the indication sign and plug base;
5. Power supply (power supply, air source, etc., according to equipment installation environment and operation conditions), and the equipment shell is reliably grounded;
![]()
![]()
![]()