logo
Thuis Productenniet destructief het testen materiaal

AC110V Magnetic Coil Flaw Detector Diameter 200mm

Certificaat
CHINA HUATEC  GROUP  CORPORATION certificaten
CHINA HUATEC  GROUP  CORPORATION certificaten
Klantenoverzichten
breed scala van NDT producten, kunnen we allemaal in huatec groep. Wij liever kopen van hen. Rudolf Shteinman, Rusland

—— Rudolf Shteinman

Ik houd van de dienst, zeer snelle reactie, het professionele werk. Aret Turkije

—— Aret Kaya

huatec Hardheidstestapparaten, zeer goede kwaliteit, we zijn zeer tevreden met de draagbare Hardheidstestapparaten RHL-50. Kumaren Govender Sotuth Afrika

—— Kumaren Govender

Ik ben online Chatten Nu

AC110V Magnetic Coil Flaw Detector Diameter 200mm

AC110V Magnetic Coil Flaw Detector Diameter 200mm
AC110V Magnetic Coil Flaw Detector Diameter 200mm

Grote Afbeelding :  AC110V Magnetic Coil Flaw Detector Diameter 200mm

Productdetails:
Plaats van herkomst: China
Merknaam: HUATEC
Certificering: ISO,CE
Modelnummer: HCDX-C200
Document: HCDX-C200 magnetic+coil+fla...al.pdf
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: 1SET
Verpakking Details: in karton
Levertijd: 5 tot 8 werkdagen na betaling
Betalingscondities: L/C, T/T, Western Union
Levering vermogen: 100 setjes per maand

AC110V Magnetic Coil Flaw Detector Diameter 200mm

beschrijving
Productnaam: Magnetische spoelfoutenmelder Voeding: AC110V, 60HZ
magnetiserende stroom: 17A, 170 toeren, 2890AT Spoelmaat: Φ 200 mm, 170 windingen
Markeren:

AC110V magnetic coil flaw detector

,

200mm diameter flaw detector

,

non-destructive testing equipment with warranty

AC110V Magnetic Coil Flaw Detector Diameter 200mm 


I. main parameter

Input current 10A, determined according to the set values of magnetization and demagnetization, the standby current is 0.5A;
Power supply AC110V, 60Hz
Magnetizing current 17A,170 turms,2890AT
Central magnetic field Max 150Gs
Coil size Φ 200mm, 170 turns
Temporary load rate > 20%


II. Function introduction

 

1, Magnetization - start the electromagnetic field to magnetize the workpiece;

2, Demagnetization - demagnetization field starts to demagnetize the workpiece;

3, Over temperature alarm - the coil has a built-in 75 temperature sensor. When the set temperature is exceeded, it enters the protection state;

 

III. Installation and commissioning

 

Installation:

1. The equipment shall be installed in a dry environment without metal dust, corrosive gas and inflammable and explosive articles;

2. The temperature of surrounding medium shall not be lower than - 10 and not higher than + 40 ;

3. The relative humidity of the air shall not be greater than 85%;

4. The pipe and wire connection between the installation equipment and each auxiliary facility shall be connected according to the indication sign and plug base;

5. Power supply (power supply, air source, etc., according to equipment installation environment and operation conditions), and the equipment shell is reliably grounded;


Commissioning:

1. After the equipment is installed in place, first check whether all connecting wires and fastening screws are loose and fall off;

2. Use instruments to measure whether the voltage at the upper end of the main switch of the machine meets the requirements of equipment installation environment and operation conditions;

3. Check each function action, manually press or toggle each function switch, and each function action of the equipment shall be executed accordingly;

4. Demagnetization effect inspection: check whether the residual magnetism after demagnetization meets the requirements;

5. After passing the commissioning and inspection, the equipment can be put into production.

 

IV. Routine maintenance

After the equipment is used, the following operations must be carried out:

1.  Turn off the power switch and cut off the power supply of the equipment;

2.  Cut off the main switch of external power supply;

3.  Clean up the oil stain on the coil surface and keep the whole equipment clean;

4.  Check the circuit connecting line, cable and fastener for looseness and aging within one month;

5.  Check whether the concentration of magnetic suspension meets the standard every day;

6.  Neutral washing must be used to clean the oil stain on the surface of the equipment;

7.  If the shell is damaged, it is forbidden to continue to use;

 

V. Flaw detection principle

 

Principles of electromagnetism

 

The magnetizing current forms an electromagnetic field through the surface of ferromagnetic workpiece (AC and half wave DC have skin effect). The existence of defects will cut off the magnetic line of force, form a leakage magnetic field and adsorb magnetic particles. Magnetic particles accumulate to form magnetic marks. The existence of defects can be judged by observing magnetic marks (magnetic marks are actually enlarged defects).

 

Longitudinal magnetization method

That is, using the coil method, the workpiece is threaded into the coil or placed between the magnetic yoke composed of two coils. When current is applied to the coil, the longitudinal magnetic field is generated in the coil and passes along the long axis of the workpiece to check the circumferential crack.